意昂体育,意昂体育二

TransformerHigh voltage cabinetLow voltage cabinetOutdoor complete equipment

mobiles Vehicular Substation

Aoply to power plant (station), substation (pon
Hotline:+86-570-4982909 销售热线:+86-570-4982880
Description
Feature
Parameter
  The overall structure design of the vehicle mounted mobiles substation is compact, with strong mobility, and can be put into use in a short time. It also has high power supply reliability, flexible operation, simple and convenient assembly, and each component can also be operated and transported separately. The semi trailer is usually in a mobiles standby state and can be dispatched upon receiving a departure command. It can be put into operation in the power grid within a few hours of reaching the designated destination, especially meeting the power supply needs of the high-voltage power grid power supply system in substation technical transformation, equipment maintenance, temporary power supply on construction sites, emergency repair, and natural disaster situations.
Product technical features:
1. Has 4 national patents, and the product technology is at the leading level in China;
2. Rated voltage: 12-40.5kV;
3. Transformer maximum capacity 20000kVA:
4. Maximum rated short time withstand current of high-voltage cabinet: 40kA;
5. Rated frequency: 50Hz;
6. Protection level: IP55;
7. The types of box structure include: prefabricated cabin structure, standard container structure, aluminum zinc coated anti-corrosion wood assembly structure, and GRC cement landscape structure;
8. Product performance: suitable for mobiles power supply, with good flexibility, convenient power supply, and safe and reliable operation; 9. Mainly used in outdoor temporary electricity, military and other application scenarioses:
10. Normal service life: 20 years;

Voltage

System voltage

10kV.35kV

High voltage side maximum workingvoltage

12kV-40.5kV

Low voltage side maximum working voltage

0.66kV

    Bated frequenc

50Hz

High voltage

switch cabinet

1min powerfrequency withstand voltage (effective value)

≥42kV、≥95kV(relatively)

4S Rated short-time withstand current

25kA(effective value)

Rated peak withstand current

80kA

Low voltage

switch cabinet

1min power frequency withstand voltage

3kV

Rated short-time withstand current

40kA

Rated peak withstand current

100kA

Protection level

High yoltage switch cabinet housing

lp55

Low voltage switch cabinet housing

p55


Copyright © 2024 KERUN INTELLIGENT CONTROL CO.LTD. All rights reserved.